Skip to content

Semtech UDP

  1. Add the gateway.
  2. Point the packet forwarder at the endpoint for its region. Both serv_port_up and serv_port_down use the same port.

    Region server_address serv_port_up / serv_port_down
    EU868 gw.chirpcloud.co.uk 32700
    US915 sub-band 2 gw.chirpcloud.co.uk 32701
  3. US915: configure the gateway for sub-band 2 (903.9–905.3 MHz + 904.6 MHz).

  4. The gateway shows as online after its first stats message.

Info

Semtech UDP does not authenticate the gateway: packets are accepted for any registered gateway EUI. For production gateways we recommend Basic Station.